Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-7 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	28
Date	08/07/14
Start Time	15:53:19
Diameter Midpoint
 11.3	724427
 11.8	858070
 12.2	812904
 12.6	816900
 13.1	828924
 13.6	830820
 14.1	838312
 14.6	844554
 15.1	848106
 15.7	853530
 16.3	835955
 16.8	819432
 17.5	809065
 18.1	798210
 18.8	767458
 19.5	731826
 20.2	683870
 20.9	635782
 21.7	576448
 22.5	515322
 23.3	451433
 24.1	380207
 25.0	315836
 25.9	254315
 26.9	197458
 27.9	146323
 28.9	105923
 30.0	73638
 31.1	50555.7
 32.2	34561.9
 33.4	23696.4
 34.6	15897.1
 35.9	11920.1
 37.2	9343.67
 38.5	8077.87
 40.0	6651.74
 41.4	5600.72
 42.9	4872.78
 44.5	4056.5
 46.1	3698.29
 47.8	3179.05
 49.6	2541.99
 51.4	2233.79
 53.3	1963.56
 55.2	1833.64
 57.3	1592.39
 59.4	1389.77
 61.5	1131.94
 63.8	1049.12
 66.1	1008.62
 68.5	944.224
 71.0	855.626
 73.7	846.808
 76.4	891.421
 79.1	751.791
 82.0	795.735
 85.1	841.301
 88.2	976.931
 91.4	1186.24
 94.7	1161.67
 98.2	995.077
101.8	1045.66
105.5	941.951
109.4	815.841
113.4	678.783
117.6	548.275
121.9	468.54
126.3	382.575
131.0	315.868
135.8	249.512
140.7	225.301
145.9	204.919
151.2	169.107
156.8	157.16
162.5	118.757
168.5	138.41
174.7	84.1149
181.1	80.5581
187.7	62.0988
194.6	68.9197
201.7	45.694
209.1	60.9187
216.7	42.134
224.7	37.2411
232.9	33.2935
241.4	34.0104
250.3	40.7977
259.5	21.3858
269.0	26.7198
278.8	17.5421
289.0	16.8242
299.6	25.574
310.6	24.3908
322.0	22.651
333.8	26.0534
346.0	9.68943
358.7	9.86594
371.8	20.4129
385.4	14.3544
399.5	15.8385
414.2	6.72954
429.4	16.6343
445.1	1.73818
461.4	7.93369
478.3	16.2921
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.6888
High Voltage	9924.64
Lower Size(nm)	11.1397
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1084.4
Median(nm)	16.3355
Mean(nm)	17.3384
Geo. Mean(nm)	16.709
Mode(nm)	11.7574
Geo. Std. Dev.	1.29737
Total Concentration(#/cm)	1.75695e+007
Comment	